Why LED
General Light Vs. LED Light
MH 250W Vs LED High-Bay Light 110W
FL 32W Vs LED Tube 18W
ACME Factory
Introduction of ACME Factory
  • ACME Factory has a facility that constantly runs 24 hours and 7 days a week.
  • The facility uses high wattages for their lighting system for 24 hours, including the day-time.
  • The current lighting has issues with the light bulbs shutting off.
  • The current lights generates too much heat, and for that reason they use more air conditioner.
  • They leave many broken lights as the way it is, because the height of the fixtures.
  • The maintenance departments have used special equipment for changing lights and spent long hours for the job.
Inquiry from ACME Factory
  • ACME factory needs low-power consumption lights
  • ACME factory needs longer life span for their lights.
Existing Lights
  • Fluorescent Lights 128Watts (32Watts X 4) X 157EA
  • Fluorescent Lights 64Watts (32Watts X 2) X 29EA
  • High Bay Lights 250Watts X 10EA
New LED Lighting System
New Lights
  • LED Tube Lights 40Watts (20Watts X 2) X 24EA
  • LED High Bay Lights 110Watts X 172EA
New Layout of the Lights Shown Below
Illuminance Simulation

Comparision
Power Consumption & Return On Investment
SpecQty.Total PowerAve. Illu.ROI
BeforeFL 32W X 4
FL 32W X 2
High-bay Light 250W
157
29
10
24.4KW121Ix
AfterLED Tube Light 20W
Highbay Light 110W
24
172
19.88KWh
20% Save
209Ix5.54 Years
AlternativeLED Tube Light 20W
Highbay Light 110W
686
10
14.82KWh
40% Save
196Ix0.81 Year